Saturday, June 29, 2019

2010 Porsche Panamera Turbo (970) V8-4.8L Turbo A L L Diagnostic Trouble Codes ( DTC ): P Code Charts Page 486

2010 Porsche Panamera Turbo (970) V8-4.8L Turbo A L L Diagnostic Trouble Codes ( DTC ): P Code Charts Page 486



0 > 800 --> < 820



4 > 830 --> < 850



25 > 980 --> < 1000



37 > 1070 --> < 1090



Diagnosis Information - PDK (Dual-Clutch Transmission)



P0712



Diagnosis information - PDK



Transmission oil temperature sensor, signal implausible



Diagnostic conditions



The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are



then tested and any faults are stored.



Possible fault causes



- Line between temperature sensor and PDK control unit faulty



- Temperature sensor faulty



- PDK control unit faulty



Fault setting conditions



- Measured sensor voltage < 1.18 V



Fault effects



- An internal temperature substitute value is used



- Transmission limp-home indication in instrument cluster



P0717



P0717



Diagnosis information - Control unit DME (DFI)



Speed sensor Manual transmission



Diagnostic conditions



- Period since engine was started > 5 Second(s)



- Clutch Closed



Possible fault causes



- Loose contact or corrosion on connectors or lines



- Short circuit to B+/ground/between lines or open circuit in the lines



- Speed sensor Manual transmission Faulty



Fault effects



- Reduction Engine torque



Selector Lever Position Implausible



P0730



Diagnosis information - PDK



Selector lever position implausible



Diagnostic conditions



The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are



then tested and any faults are stored.



- Ignition on



Possible fault causes



- PDK control unit faulty



- Selector lever control unit faulty



- Serial line between PDK control unit and selector lever faulty



Fault setting conditions



- Signal from CAN does not match serial data signal



Fault effects



- Transmission limp-home indication in instrument cluster