2010 Porsche Panamera Turbo (970) V8-4.8L Turbo A L L Diagnostic Trouble Codes ( DTC ): P Code Charts Page 487

2010 Porsche Panamera Turbo (970) V8-4.8L Turbo A L L Diagnostic Trouble Codes ( DTC ): P Code Charts Page 487



Interchange Detected



P0730



Diagnosis information - PDK



Interchange detected



Diagnostic conditions



The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are



then tested and any faults are stored.



- Ignition on



Possible fault causes



- Control unit is installed in the wrong vehicle



Fault setting conditions



- VIN in the control unit does not match the VIN on the CAN



Fault effects



- Adaptation values of the transmission are invalid



Double Fault: Two Faults Demand Alternative Measures With Equal Priority Rating



P0730



Diagnosis information - PDK



Double fault: two faults demand alternative measures with equal priority rating



Diagnostic conditions



The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are



then tested and any faults are stored.



- Ignition on



Possible fault causes



- Analyse fault cause for faults also entered



Fault setting conditions



- Inadmissible combination of alternative measures



Fault effects



- Emergency hold function



- Transmission limp-home indication in instrument cluster control unit



Input Shaft Overspeed



P0730



Diagnosis information - PDK



Input shaft overspeed



Diagnostic conditions



The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are



then tested and any faults are stored.



- Ignition on



Possible fault causes



- Speed sensors faulty



- Lines faulty



Fault setting conditions



- Rotational speed of shaft 1 or shaft 2 below threshold value



- Rotational speed of shaft 1 or shaft 2 above threshold value



Fault effects



- No power transmission