2010 Porsche Panamera Turbo (970) V8-4.8L Turbo A L L Diagnostic Trouble Codes ( DTC ): P Code Charts Page 618

2010 Porsche Panamera Turbo (970) V8-4.8L Turbo A L L Diagnostic Trouble Codes ( DTC ): P Code Charts Page 618



Fault setting conditions



- Engine torque outside the permissible range



- Engine speed outside the permissible range



- Selector lever in [P]



- Transmission oil temperature outside the permissible range



- Teach-in cancelled



Fault effects



- Clutches open



- Transmission limp-home display in the instrument cluster control unit



Fault remedy



- Perform calibration



- Engine running



- Selector lever [P]



- Transmission pan temperature >= 60 锟斤拷C (140 锟斤拷F)



Variant Coding Not Valid



P1749



Diagnostic information - PDK



Variant coding not valid



Diagnostic conditions



The control unit first tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are then



tested and any faults are stored.



- Ignition on



Possible fault causes



- Incorrect program and data versions programmed



- Incorrect coding in vehicle order



Fault setting conditions



- Programmed data record is not valid



- Coding in vehicle order is not valid



Fault effects



- No power transmission



- Transmission limp-home display in the instrument cluster control unit



Fault remedy



- Update of the correct program version according to country identifier



- Check of the vehicle order



PDK Control Unit, Supply Voltage Less Than 9 V



P1752



Diagnosis information - PDK



PDK control unit, supply voltage < 9 V



Diagnostic conditions



The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are



then tested and any faults are stored.



- Ignition on



- Engine at idle speed



Possible fault causes



- Control unit power supply line faulty



- Connector corroded



- Battery faulty



- Generator faulty



Fault setting conditions



- Supply voltage > 7 V --> < 9 V