2010 Porsche Panamera Turbo (970) V8-4.8L Turbo A L L Diagnostic Trouble Codes ( DTC ): P Code Charts Page 597

2010 Porsche Panamera Turbo (970) V8-4.8L Turbo A L L Diagnostic Trouble Codes ( DTC ): P Code Charts Page 597



Double fault: two faults demand alternative measures with equal priority rating



Diagnostic conditions



The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are



then tested and any faults are stored.



- Ignition on



Possible fault causes



- Analyse fault cause for faults also entered



Fault setting conditions



- Inadmissible combination of alternative measures



Fault effects



- Emergency hold function



- Transmission limp-home indication in instrument cluster control unit



Input Shaft Overspeed



P1715



Diagnosis information - PDK



Input shaft overspeed



Diagnostic conditions



The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are



then tested and any faults are stored.



- Ignition on



Possible fault causes



- Speed sensors faulty



- Lines faulty



Fault setting conditions



- Rotational speed of shaft 1 or shaft 2 below threshold value



- Rotational speed of shaft 1 or shaft 2 above threshold value



Fault effects



- No power transmission



- Limp-home message in instrument cluster



With P0604



P1715



Diagnosis information - PDK



PDK control unit, internal fault



Diagnostic conditions



The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are



then tested and any faults are stored.



- Ignition on



Possible fault causes



- Control unit faulty



Fault setting conditions



- Internal diagnostic routine returns fault



Fault effects



- Power supply switch-off for pressure regulator



- Solenoid valve power supply switch-off



- Hydraulic control is switched off



- Start enable only in position P