2010 Porsche Panamera Turbo (970) V8-4.8L Turbo A L L Diagnostic Trouble Codes ( DTC ): P Code Charts Page 734
- Power supply switch-off, pressure regulator for system pressure and synchro selection
- Power supply switch-off, solenoid valves
- Pressure regulator for system pressure and synchro selection, switch-off
- Solenoid valves switch-off
- Last gear held
- Transmission limp-home indication in instrument cluster control unit
Pressure Regulator 4 (System Pressure), Open Circuit
P2720
Diagnosis information - PDK
Pressure regulator 4 (system pressure), open circuit
Diagnostic conditions
The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are
then tested and any faults are stored.
- Ignition on
- The following fault is not detected: P1832
- The following fault is not detected: P183A
- Pressure regulator 4 active
Possible fault causes
- Line between pressure regulator 4 and PDK control unit faulty
- Pressure regulator 4 faulty
- PDK control unit faulty
Fault setting conditions
- Internal current measurement, pressure regulator 4: current consumption = 0 mA
- Line resistance between pressure regulator 4 and PDK control unit > 1 MOhm
Fault effects
- System pressure control switch-off
- Pressure regulator 4 switch-off
- Engaged gear is held until vehicle stops.
- Moving off possible only in 2nd gear
- Transmission limp-home indication in instrument cluster control unit
Pressure Regulator 4 (System Pressure), Short Circuit To Ground
P2720
Diagnosis information - PDK
Pressure regulator 4 (system pressure), short circuit to ground
Diagnostic conditions
The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are
then tested and any faults are stored.
- Ignition on
- The following fault is not detected: P1832
- The following fault is not detected: P183A
Possible fault causes
- Line between pressure regulator 4 and PDK control unit, short circuit to ground
- Pressure regulator 4 faulty
- PDK control unit faulty
Fault setting conditions
- Internal current measurement, actuator solenoid R/P: current consumption = 0 mA
- Pressure regulator 4, internally measured control current = 0 mA
- Pressure regulator 4, measured voltage = 0 V
Fault effects
- Power supply switch-off for pressure regulators 4 to 6
- Power supply switch-off for solenoid valves 1 and 2
- Pressure regulator 4 switch-off
- Pressure regulator 5 switch-off