2010 Porsche Panamera Turbo (970) V8-4.8L Turbo A L L Diagnostic Trouble Codes ( DTC ): P Code Charts Page 754
The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are
then tested and any faults are stored.
- Ignition on
- The following fault is not detected: P1832
- The following fault is not detected: P183A
- Pressure regulator 6 active
Possible fault causes
- Line between pressure regulator 6 and PDK control unit faulty
- Pressure regulator 6 faulty
- PDK control unit faulty
Fault setting conditions
- Internal current measurement, pressure regulator: current consumption = 0 mA
- Line resistance between pressure regulator 6 and PDK control unit > 1 MOhm
Fault effects
- Pressure regulator 6 switch-off
- Engaged gear is held until vehicle stops.
- Moving off possible only in following gear: 3rd gear
- Transmission limp-home indication in instrument cluster control unit
Setpoint Definitions
P2738
Setpoint definitions
NOTE: The specified values and value ranges correspond to the OK state in each case.
Line test setpoints
Short circuit to B+:
- Setpoint voltage -0.5 V --> +0.5 V
Short circuit to ground:
- Setpoint resistance > 0.9 MOhm
Open circuit:
- Setpoint resistance < 2 Ohm
NOTE: The specified values apply only at an ambient temperature of approx. 20 锟斤拷C (68 锟斤拷F) (room temperature).
Pressure regulator setpoints
- Internal resistance > 3.7 --> < 6.4 Ohm
Diagnosis Information - PDK (Dual-Clutch Transmission)
P2738
Diagnosis information - PDK
Pressure regulator 6 (synchro selection gear: 4, 2, 1, 7), short circuit to ground
Diagnostic conditions
The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are
then tested and any faults are stored.
- Ignition on
- The following fault is not detected: P1832
- The following fault is not detected: P183A
Possible fault causes
- Line between pressure regulator 6 and PDK control unit, short circuit to ground
- Pressure regulator 6 faulty
- PDK control unit faulty
Fault setting conditions
- Internal current measurement, actuator solenoid R/P: current consumption = 0 mA
- Pressure regulator 6, internally measured control current = 0 mA
- Pressure regulator 6, measured voltage = 0 V