Saturday, June 15, 2019

2010 Porsche Panamera Turbo (970) V8-4.8L Turbo A L L Diagnostic Trouble Codes ( DTC ): P Code Charts Page 530

2010 Porsche Panamera Turbo (970) V8-4.8L Turbo A L L Diagnostic Trouble Codes ( DTC ): P Code Charts Page 530



- Internal current measurement, actuator solenoid R/P: current consumption = 0 mA



- Pressure regulator 2, control current > 850 mA



Fault effects



- Pressure regulator 2 switch-off



- Engaged gear is held until vehicle stops.



- Moving off possible only in 3rd gear



- Transmission limp-home indication in instrument cluster control unit



Pressure Regulator 2 (Clutch 2), Short Circuit To Ground



P0967



Diagnosis information - PDK



Pressure regulator 2 (clutch 2), short circuit to ground



Diagnostic conditions



The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are



then tested and any faults are stored.



- Ignition on



- The following fault is not detected: P1831



- The following fault is not detected: P1839



Possible fault causes



- Line between pressure regulator 2 and PDK control unit, short circuit to ground



- Pressure regulator 2 faulty



- PDK control unit faulty



Fault setting conditions



- Internal current measurement, actuator solenoid R/P: current consumption = 0 mA



- Pressure regulator 2, internally measured control current = 0 mA



- Pressure regulator 2, measured voltage = 0 V



Fault effects



- Power supply switch-off for pressure regulators 2 and 3



- Pressure control switch-off, clutch 2



- Pressure control switch-off for lubrication pressure



- Engaged gear is held until vehicle stops.



- Moving off possible only in 3rd gear



- Transmission limp-home indication in instrument cluster control unit



With P17AA



P0967



Diagnosis information - PDK



Pressure regulator 2 (clutch 2), shunt



Diagnostic conditions



The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are



then tested and any faults are stored.



- Ignition on



- The following fault is not detected: P0964



- The following fault is not detected: P0966



- The following fault is not detected: P0967



Possible fault causes



- Shunt circuit in line between pressure regulator 2 and PDK control unit



- Pressure regulator 2 faulty



- PDK control unit faulty



Fault setting conditions



- Actual pressure regulator current < setpoint current (maximum deviation = 35 mA)



Fault effects



- Power supply switch-off, pressure regulator clutch 2



- Power supply switch-off, pressure regulator for lubrication pressure