Wednesday, August 28, 2019

2010 Porsche Panamera Turbo (970) V8-4.8L Turbo A L L Diagnostic Trouble Codes ( DTC ): P Code Charts Page 485

2010 Porsche Panamera Turbo (970) V8-4.8L Turbo A L L Diagnostic Trouble Codes ( DTC ): P Code Charts Page 485



Transmission oil temperature sensor, signal implausible



Diagnostic conditions



The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are



then tested and any faults are stored.



- Ignition on



- The following fault is not saved: P1831



- The following fault is not saved: P1832



- The following fault is not saved: P1839



- The following fault is not saved: P183A



Possible fault causes



- The measured oil temperature deviates from the calculated temperature



Fault setting conditions



- The measured temperature does not match the calculated temperature



Fault effects



- The calculated temperature value is used



- Transmission limp-home indication in instrument cluster



With P0712



P0712



Diagnosis information - PDK



Transmission oil temperature sensor, signal implausible



Diagnostic conditions



The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are



then tested and any faults are stored.



Possible fault causes



- Line between temperature sensor and PDK control unit faulty



- Temperature sensor faulty



- PDK control unit faulty



Fault setting conditions



- Measured sensor voltage < 1.18 V



Fault effects



- An internal temperature substitute value is used



- Transmission limp-home indication in instrument cluster



Setpoint Definitions



P0712



Setpoint definitions



NOTE: The specified values and value ranges correspond to the OK state in each case.



Line test setpoints



Short circuit to B+:



- Setpoint voltage -0.5 V --> +0.5 V



Short circuit to ground:



- Setpoint resistance > 0.9 MOhm



Open circuit:



- Setpoint resistance < 2 Ohm



NOTE: The specified values apply only at an ambient temperature of approx. 20 锟斤拷C (68 锟斤拷F) (room temperature).



Temperature sensor setpoints



Temperature [锟斤拷C] Resistance [Ohm]