Friday, October 4, 2019

2010 Porsche Panamera Turbo (970) V8-4.8L Turbo A L L Diagnostic Trouble Codes ( DTC ): P Code Charts Page 444

2010 Porsche Panamera Turbo (970) V8-4.8L Turbo A L L Diagnostic Trouble Codes ( DTC ): P Code Charts Page 444



- Engine running (stable engine speed 400 rpm)



Possible fault causes



- Control unit power supply lines faulty



- Connector corroded



- Generator faulty



Fault setting conditions



- Supply voltage < 7 V



Fault effects



- Power supply switch-off, pressure regulators and solenoid valves



- All pressure regulators and solenoid valves, switch-off



- Start enable only in position P



- Substitute value for accelerator pedal value



- Substitute value for brake



- No speed control



- No emergency program diagnosis



- Emergency hold function



- Transmission limp-home indication in instrument cluster control unit



Diagnosis Information - PDK (Dual-Clutch Transmission)



P0562



Diagnosis information - PDK



PDK control unit, supply voltage < 9 V



Diagnostic conditions



The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are



then tested and any faults are stored.



- Ignition on



- Engine at idle speed



Possible fault causes



- Control unit power supply line faulty



- Connector corroded



- Battery faulty



- Generator faulty



Fault setting conditions



- Supply voltage > 7 V --> < 9 V



Fault effects



- Power supply switch-off for pressure regulator



- Solenoid valve power supply switch-off



PDK control unit, supply voltage less than 9 V



P0563



Diagnosis information - PDK



PDK control unit, supply voltage < 9 V



Diagnostic conditions



The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are



then tested and any faults are stored.



- Ignition on



- Engine at idle speed



Possible fault causes



- Control unit power supply line faulty



- Connector corroded



- Battery faulty



- Generator faulty



Fault setting conditions