2010 Porsche Panamera Turbo (970) V8-4.8L Turbo A L L Diagnostic Trouble Codes ( DTC ): P Code Charts Page 746
- Setpoint resistance > 0.9 MOhm
Open circuit:
- Setpoint resistance < 2 Ohm
NOTE: The specified values apply only at an ambient temperature of approx. 20 锟斤拷C (68 锟斤拷F) (room temperature).
Pressure regulator setpoints
- Internal resistance > 3.7 --> < 6.4 Ohm
Pressure Regulator 5 (Synchro Selection Gear: 6, R, 3, 5), Short Circuit To B+
P2730
Diagnosis information - PDK
Pressure regulator 5 (synchro selection gear: 6, R, 3, 5), short circuit to B+
Diagnostic conditions
The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are
then tested and any faults are stored.
- Ignition on
- The following fault is not detected: P1832
- The following fault is not detected: P183A
Possible fault causes
- Line between pressure regulator 5 and PDK control unit, short circuit to B+
- Pressure regulator 5 faulty
- PDK control unit faulty
Fault setting conditions
- Internal current measurement, pressure regulator 5: current consumption = 850 mA
Fault effects
- Pressure regulator 5 switch-off
- Engaged gear is held until vehicle stops
- Moving off possible only in 2nd gear
- Transmission limp-home indication in instrument cluster control unit
With P17AD
P2730
Diagnosis information - PDK
Electrical pressure adjuster 5, shunt
Diagnostic conditions
The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are
then tested and any faults are stored.
- Ignition on
- The following fault is not detected: P1832
- The following fault is not detected: P183A
- The following fault is not detected: P1842
Possible fault causes
- Shunt circuit in line between pressure regulator 5 and PDK control unit
- Pressure regulator 5 faulty
- PDK control unit faulty
Fault setting conditions
- Actual pressure regulator current < setpoint current (maximum deviation = 35 mA)
Fault effects
- Power supply switch-off, pressure regulator for system pressure and synchro selection
- Power supply switch-off, solenoid valves
- Pressure regulator for system pressure and synchro selection, switch-off
- Solenoid valves switch-off