- The following fault is not detected: P1838



Possible fault causes



- Line between pressure regulator 1 and PDK control unit faulty



- Pressure regulator 1 faulty



- PDK control unit faulty



Fault setting conditions



- Internal current measurement, pressure regulator 1: current consumption = 0 mA



- Pressure regulator 1, measured voltage = 0 V



Fault effects



- Pressure control switch-off, clutch 1



- Engaged gear is held until vehicle stops.



- Moving off possible only in 2nd gear



- Transmission limp-home indication in instrument cluster control unit



Pressure Regulator 1 (Clutch 1), Open Circuit



P17A1



Diagnosis information - PDK



Pressure regulator 1 (clutch 1), open circuit



Diagnostic conditions



The control unit initially tests internal function sequences when the ignition is switched on (terminal 15). If they are OK, all diagnosable outputs are



then tested and any faults are stored.



- Ignition on



- The following fault is not detected: P1830



- The following fault is not detected: P1838



Possible fault causes



- Open circuit in line between pressure regulator 1 and PDK control unit



- Pressure regulator 1 faulty



- PDK control unit faulty



Fault setting conditions



- Internal current measurement, pressure regulator 1: current consumption = 0 mA



- Line resistance between pressure regulator 1 and PDK control unit > 1 MOhm



Fault effects



- Pressure control switch-off, clutch 1



- Clutch 1 opening



- Engaged gear is held until vehicle stops.



- Moving off possible only in 2nd gear



- Transmission limp-home indication in instrument cluster control unit



Setpoint Definitions



P17A1



Setpoint definitions



NOTE: The specified values and value ranges correspond to the OK state in each case.



Line test setpoints



Short circuit to B+:



- Setpoint voltage -0.5 V --> +0.5 V



Short circuit to ground:



- Setpoint resistance > 0.9 MOhm



Open circuit:



- Setpoint resistance < 2 Ohm



NOTE: The specified values apply only at an ambient temperature of approx. 20 锟斤拷C (68 锟斤拷F) (room temperature).



Pressure regulator setpoints



- Internal resistance > 3.7 --> < 6.4 Ohm